全自动超声波清洗机一般会有定时或加热功能,我们介绍了几种th系列超声波清洗机的几种常见定时配置,今天我们就再介绍几种常见的加热配置,希望能通过此文让您对超声波清洗机有个更好的了解。
Automatic ultrasonic cleaning machine generally has timing or heating function, we introduced several common timing configuration of th series ultrasonic cleaning machine, today we will introduce several common heating configuration, hope to let you have a better understanding of ultrasonic cleaning machine through this article.
1、数控面板加热
1. Numerical control panel heating
一般实验室用的数控超声波清洗机,带有加热功能的机型,如th-300bq,就是数控按键加热。数控区显示当前温度,可以设定温度值,当达到加热值是自动停止加热。此种加热一般是用硅胶板加热。
The general laboratory used numerical control ultrasonic cleaning machine, with heating function, such as th-300bq, is the numerical control key heating. The current temperature is displayed in the numerical control area, and the temperature value can be set. When the heating value is reached, the heating will be stopped automatically. This kind of heating is generally with silica gel plate heating.


2、温控仪加热
2. Temperature controller heating
分体超声波清洗机根据使用情况有用温控仪加热,使用方法如下:按下加热开关,温控仪将显示测量温度与控制温度。上面显示的是测量温度,下面显示的是控制温度,当测量温度低于控制温度时,温控仪上out灯亮,加热指示灯亮,设备处于加热状态;当测量温度高于控制温度时,温控仪上out灯灭,加热指示灯熄灭,设备停止加热。控制温度设置方法:按拨码键设定控制温度,如058,控制温度为58度。此种一般是用加热管加热。
Separate ultrasonic cleaning machine according to the use of useful temperature controller heating, use the following: press the heating switch, temperature controller will display the measured temperature and control temperature. When the measured temperature is lower than the control temperature, the out light on the temperature controller is on, the heating indicator is on, and the equipment is in the heating state; When the measured temperature is higher than the control temperature, the out light on the temperature controller goes out, the heating indicator goes out, and the equipment stops heating. Control temperature setting method: press the dial key to set the control temperature, such as 058, the control temperature is 58 degrees. This kind of heating pipe is usually used for heating.
3、机械温控
3. Mechanical temperature control
普通台式超声波清洗机一般用机械温控,也就是旋钮调节温度,如th-500q型台式超声波清洗机,温度调节范围为常温-80度。
Ordinary desktop ultrasonic cleaning machine generally uses mechanical temperature control, that is, knob to adjust the temperature, such as th-500q desktop ultrasonic cleaning machine, the temperature range is - 80 ℃.
相关文章
-
10万就能做!可定制通过式喷淋清洗机,解决各类清洗难题 2026-01-28
-
工业清洗想省心?这款喷淋清洗机,轻松搞定各类零件污渍 2026-01-27
-
多槽手动超声波清洗机的功率和频率的关系 2026-01-23
-
全自动超声波清洗机清洗器械时最佳水温需根据污垢程度和清洗需求决定 2026-01-22
-
超声波清洗机的结构与组成 2026-01-20
-
低温废水回收设备:工业废水的终结者 2026-01-16
-
喷淋清洗机选择时需要根据清洗目的、清洗对象、清洗量、清洗方式、清洗效果等来确定适合的型号 2026-01-13
-
碳氢清洗机因高能源利用效率、环保性能、适应性与经济性倍受好评 2026-01-12
-
清洗治具时,CNC高压清洗机如何防止治具变形或损坏? 2026-01-10
-
真空碳氢清洗机清洗金属波纹管路非常环保、洁净度高、清洗高效 2026-01-10

新闻中心




常见问题







鲁公网安备37011202000628号